Cleantech & Investment

CATL details Tener Sodium specs: 30+ MWh blocks, 7.5 MW output

CATL confirms 30+ MWh, 7.5 MW Tener Sodium specs and a summer 2027 overseas delivery window, with modeled EPC savings of 9.2% against its LFP EnerX system.

Clarifying CATL Tener Sodium, with new specifications and availability
Clarifying CATL Tener Sodium, with new specifications and availabilityValdasMiskinis / pixabay

Waypoints

  1. Tener Sodium blocks deliver 30+ MWh at 7.5 MW over four hours; eight-cabinet block measures 18.2 m x 7 m x 3.5 m

  2. CATL models 9.2% lower EPC costs and 32% less land area for a 500 MWh project versus its EnerX LFP system

  3. Overseas deliveries are set for summer 2027, following an August 2027 production window; China deliveries have begun

  4. In-house Terapower PCS rated at 265 kW with peak efficiency of at least 99.2%

  5. Each cabinet weighs 44-45 metric tons, up from the 42 metric tons quoted at the June Munich launch

CATL has confirmed its Tener Sodium battery energy storage system delivers more than 30 MWh per block, with a rated power output of 7.5 MW over four hours, and an overseas delivery window of summer 2027. The figures come from an Oct. 29 ATA Insights webinar presented by CATL energy storage product solution manager David Santiago, which filled in datasheets for the sodium-ion system and its in-house power conversion hardware nearly five months after the product's June launch at The Smarter E in Munich.

How is the system configured?

The block ships in pairs. Buyers can specify two, four, six or eight cabinets. The full eight-cabinet block sits in two back-to-back rows of four and measures 18.2 m across, 7 m deep and 3.5 m high.

Santiago put each cabinet at roughly 4.5 m (15 feet) long and 44 to 45 metric tons. That works out to about 4 MWh per cabinet in the eight-cabinet configuration. At the Munich launch, CATL had quoted module weight at about 42 metric tons — a figure that has since grown.

CATL plans the same cabinets and layout for a lithium iron phosphate (LFP) version. Santiago sized that variant at about 50 MWh across eight cabinets and said developers choose the chemistry at project design stage. The company is prioritizing sodium-ion certification; the LFP version follows.

What are the core battery specs?

The datasheet lists:

  • Rated energy: 30+ MWh, charge and discharge up to 0.25P, or 7.5 MW for four hours (Santiago did not state a revised power figure if final capacity reaches 32 MWh)
  • Voltage: rated 1,166.88 V DC, range 612 V to 1,387.2 V
  • Round-trip efficiency: 95% at 25°C and 0.25P
  • Degradation: 70% state of health after 20 years under a 0.25P duty cycle
  • Operating range: −35°C to +55°C; storage from −35°C to +60°C
  • Noise: 65 dB(A) or less; IP55 ingress protection; C5 corrosion protection with C4 optional; operation to 4,000 m without derating
  • Communications: CAN, Modbus TCP/IP, RS485

At launch, CATL reported 15,000 cycles at 25°C and more than 10,000 at 45°C, plus more than 92% capacity retention at −20°C.

What does the Terapower converter add?

CATL pairs the battery with its own Terapower 265 kW PCS, which combines bidirectional DC/DC conversion — boosting voltage at the low end of the battery's range — with the power conversion stage. Third-party PCS makers remain an option.

The converter accepts 600 V to 1,500 V DC at up to 222 A and outputs 690 V AC at 50 or 60 Hz. Peak efficiency is at least 99.2%; full-load efficiency at least 98.5%; current harmonic distortion below 3% at rated load. The liquid-cooled unit is rated IP66, operates from −40°C to +60°C up to 5,000 m, and derates above 50°C and above 3,000 m. Interfaces include RS485, Ethernet and CAN, with IEC 61850 and Modbus TCP support. Santiago said the PCS ties into the battery's thermal management and its load is counted in auxiliary consumption.

How does it compare with CATL's LFP EnerX?

Against the EnerX 0.25P LFP system, CATL claims the sodium-ion cells generate 27.2% less heat per unit of energy at beginning of life and 32.7% less at end of life. For a 50 MWh station, DC-side refrigeration capacity falls to 490 kW from 720 kW, noise drops from 75 dB(A) to 65 dB(A), and auxiliary power share is 10% lower. CATL has separately pegged Tener Sodium auxiliary consumption at 1%, against an industry average it puts at 2%.

Webinar degradation curves showed 71.3% capacity retention after 20 years at one cycle per day and 65.2% after 19 years at two cycles per day. Santiago called those curves older estimates and said CATL has since obtained "better" data as the product matures.

For a 500 MWh project, CATL modeled 16 Tener Sodium blocks against 23 EnerX blocks. The sodium layout covers 6,630 m² versus about 9,700 m² — a reduction of roughly 32%. Per block, Tener Sodium takes 158.5 m² against 180.6 m² for EnerX, an areal density of 0.197 MWh/m² versus 0.125 MWh/m².

What are the modeled cost savings?

CATL estimated 9.2% lower engineering, procurement and construction costs for the sodium layout. The breakdown: EPC equipment costs down 12%, civil works excluding labor down 16%, labor down 17%. Design and management fees were held equal. The estimate excludes transport, the substation and what CATL labels "DC/AC side" costs. CATL's other LFP products, including Tener Stack, likely compete more closely with Tener Sodium than EnerX does.

One open question is freight. At 3.5 m high, each cabinet exceeds the height of a standard high-cube shipping container, and Santiago noted the shipping method and cost remain unresolved.

Deliveries have already begun in China. Overseas deliveries follow summer 2027, after an August 2027 production window. Santiago said CATL is receiving "a lot of orders."

via pv-magazine-australia.com (Source)

Share this article:

More from Rebecca Stone

Rebecca Stone

Show full bio

News editor covering companies, deals and strategy in Circular economy and the environmental industry at Circular Wire.

501 articles

Nearby routes

« Previous article